Fleck 5600SXT

FEATURES/BENEFITS

Continuous service flow rate of 20 GPM with a backwash of 7 GPM

Backwash capability accommodates softener tanks up to 12″ and filter up to 10″ in diameter

Fully adjustable 3- or 5-cycle control for efficient and reliable water treatment system

Super capacitor for keeping time of day during power outage

Time-tested, hydraulically balanced piston for service and regeneration

Diagnostics for historical valve performance

LCD display alternates between time of day, volume remaining or days until regeneration

Programming stored in memory and will not be lost due to power outages

OPTIONS

Filter or softener control valves

Downflow co-current or upflow counter-current regeneration

Brine cam auxiliary switch

Plumbing connections in 3/4″to 1-1/4″ NPT, BSP, and sweat

Fiber-reinforced polymer or stainless steel bypass valve

Programmable regeneration types for increased flexibility

Downflow double backwash cam for reduced hardness leakage

Swivel attachment for 360° rotation of power head

SXT-Large LCD display and user-selectable time clock or metered
function; usable for filtration and
softener systems

VALVE SPECIFICATIONS

Valve Material                        Fiber-reinforced polymer

Inlet/Outlet                            3/4″, 1″, or 1-1/4″ NPT/
BSP/Sweat

Cycles                                      5

FLOW RATES (50 PSI INLET) – VALVE ALONE

Continuous                              20 GPM (4.5 m3/h)
15 psi drop    

Peak                                        26 GPM (5.9 m3/h)
25 psi drop                              

Cv                                            5.0
flow at 1 psi drop

Max. Backwash                        7 GPM (1.6 m3/h)
25 psi drop

REGENERATION

Downflow/Upflow                         Both

Adjustable Cycles                          Yes

Time Available
               SXT:                                0 – 199min/cycle

METER INFORMATION

Meter Accuracy
               3/4″ Paddle/Turbine:     0.25 – 15 GPM ± 5%
                                                    (0.06 – 3 m3/h)

Meter Capacity Range
                SXT:                             1 – 999,900 gal
                                                    (0 – 3,785 m3)

Dimensions

Distributor Pilot                    0.8125″ or 1.05″ O.D.         
                                              (26.7 mm)       

Drain Line                             1/2″ NPTF

Brine Valve
              1600:                       3/8″

Injector System                      1600

Mounting Base                       2.5″– 8 NPSM

Height From
Top of Tank                             7.5″ (190 mm)

Riser Tube Diameter               3/4″ (19 mm)

Riser Height                           Flush with top of tank

TYPICAL APPLICATIONS

Water Softener                       6 – 12″ diameter

Filters                                     8 – 10″ diameter

ADDITIONAL INFORMATION

Electrical Rating                    24V
                                              50/60 Hz

Max. VA                                  8.4

Estimated Shipping Weight
              Time Clock:              6 lbs

              Metered Valve:         7 lbs

Pressure
              Hydrostatic:             300 psi
                                              (20 bar

              Working:                  20 – 125 psi
                                              (1.4 – 8.5 bar

Temperature
              Cold Water Valve:     34 – 110°F (1 – 43°C)